By operating environment · Narrow-aisle stackers
Cold-store VNA stacker rated for −25 °C
In short
A cold-store stacker is not a standard truck with thicker paint. The SF-1400M-CS is rated for continuous work at −25 °C, with a heated operator cabin, cold-rated electrics, low-temperature lubricants and 80 V / 700 Ah traction battery, lifting 1,400 kg to 12,500 mm in a 1,650 mm aisle.
- Rated for continuous operation at −25 °C, not intermittent entry
- Heated cabin, cold-rated wiring and low-temperature lubricants
- 1,400 kg to 12,500 mm in a 1,650 mm guided aisle
- 80 V / 700 Ah lead-acid battery, Li-ion optional
- Overhead guard 2,635 mm; overall 3,955 × 1,502 mm
−25 °C continuous
The rating is for a shift inside the freezer, not a quick pass.
Heated cabin
The operator works a full shift without a thermal suit.
Cold-rated electrics
Wiring, seals and lubricants specified for low temperature.
12.5 m in the freezer
High-bay freezing at 1,400 kg per pallet.
Cold-store VNA against a standard man-up truck
| Item | SF-1400M-CS | SF-1200M man-up |
|---|---|---|
| Rated temperature | −25 °C continuous | Ambient |
| Cabin | Heated | Guarded, unheated |
| Capacity | 1,400 kg | 1,200 kg |
| Lift height | 12,500 mm | 9,780 mm |
| Aisle (1200×1200) | 1,650 mm | 1,650 mm |
| Battery | 80 V / 700 Ah | 80 V / 420 Ah |
In the field
Photographed on customer floors


Buyer questions
What buyers ask before ordering
What changes on a freezer-rated VNA truck?
+
The electricals are cold-rated, the lubricants are low-temperature, the cabin is heated, and the battery capacity is sized for the load the cold puts on it. Steel and hydraulics also need low-temperature specification — a standard truck will run, badly, until a seal fails.
Can a standard stacker be used in a freezer?
+
For short entries it may start, but continuous −25 °C work takes the battery down, stiffens seals and fogs displays. A cold-store build is the difference between a truck that works a shift and one that stops mid-aisle.
How much capacity does cold take away?
+
The published rating of the SF-1400M-CS is 1,400 kg at a 1,650 mm aisle and 12,500 mm lift, so the cold rating is already inside those figures. Leave margin for ice build-up on the pallet and the rack.
Does the aisle need different protection in a freezer?
+
Yes — impact protection has to survive the temperature, floor joints move more, and lighting is usually dimmer. That is part of the layout work, not a truck option.
Send us the load. We will size the machine.
Load dimensions, weight and the rate the line has to keep up with are enough for a machine recommendation and a firm quotation.